Part Number Hot Search : 
48E48BS2 PL0721 BAV19W 332J1000 BR256L LBT42304 ERIES 0040C
Product Description
Full Text Search
 

To Download MY2IN-CR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 General-purpose Relay
MY
Versatile, Multi-featured, Miniature Power Relay for Sequence Control and Power Switching Applications
* Models with lockable test buttons now available. * Multiple features available, including operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. * Environment-friendly cadmium-free contacts. * Wide range of Sockets (PY, PYF Series) and optional parts. * Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A * Provided with nameplate. * RoHS Complaint.
LR
Ordering Information
Relays
Standard Coil Polarity
Type Contact form Model Plug-in socket/solder terminals Standard with LED indicator Standard DPDT 4PDT 4PDT (bifurcated) With built-in diode (DC only) With built-in CR (220/240 VAC, 110/120 VAC only) DPDT 4PDT 4PDT (bifurcated) DPDT 4PDT 4PDT (bifurcated) MY2N MY4N MY4ZN MY2N-D2 MY4N-D2 MY4ZN-D2 MY2N-CR MY4N-CR MY4ZN-CR With LED indicator and lockable test button MY2IN MY4IN MY4ZIN MY2IN-D2 MY4IN-D2 MY4ZIN-D2 MY2IN-CR MY4IN-CR MY4ZIN-CR Without LED indicator MY2 MY4 MY4Z -------------
Reverse Coil Polarity
Type Contact form Model Plug-in socket/solder terminals With LED indicator Standard (DC only) DPDT 4PDT 4PDT (bifurcated) With built-in diode (DC only) DPDT 4PDT 4PDT (bifurcated) MY2N1 MY4N1 MY4ZN1 MY2N1-D2 MY4N1-D2 MY4ZN1-D2 With LED indicator and lockable test button MY2IN1 MY4IN1 MY4ZIN1 MY2IN1-D2 MY4IN1-D2 MY4ZIN1-D2
Note: 1. When ordering, add the rated coil voltage to the model number(s), followed by "(S)". Rated coil voltages are given in the coil ratings table. Example: MY2 AC12(S) Rated coil voltage 2. Arc barrier standard on all four-pole relays. 3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for details.
General-purpose Relay
MY
259
Specifications
Coil Ratings
Rated voltage Rated current 50 Hz AC 6 V* 12 V 24 V 48/50 V* 110/120 V 220/240 V DC 6 V* 12 V 24 V 48 V* 100/110 V 214.1 mA 106.5 mA 53.8 mA 24.7/ 25.7 mA 4.8/5.3 mA 151 mA 75 mA 37.7 mA 18.8 mA 9.0/9.9 mA 60 Hz 183 mA 91 mA 46 mA 21.1/ 22.0 mA 4.2/4.6 mA 12.2 46 180 788 4,430 18,790 39.8 160 636 2,560 11,100 Coil resistance Inductance (reference value) Arm. OFF 0.04 H 0.17 H 0.69 H 3.22 H 19.20 H 83.50 H 0.17 H 0.73 H 3.20 H 10.60 H 45.60 H Arm. ON 0.08 H 0.33 H 1.30 H 5.66 H 32.1 H 136.4 H 0.33 H 1.37 H 5.72 H 21.0 H 86.2 H 10% min. 0.9 to 1.1 VA (60 Hz) 0.9 W Must operate Must release Max. voltage % of rated voltage 80% max. 30% min. 110% Power consumption (approx.) 1.0 to 1.2 VA (60 Hz)
9.9/10.8 mA 8.4/9.2 mA
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for rated currents and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 5. Rated voltage denoted by "*" will be manufactured upon request. Ask your OMRON representative.
Contact Ratings
Item 2-pole Resistive load (cos = 1) Rated load Carry current 5 A, 250 VAC 5 A, 30 VDC 10 A (see note) Inductive load (cos = 0.4, L/R = 7 ms) 2 A, 250 VAC 2 A, 30 VDC 4-pole Resistive load Inductive load (cos = 1) (cos = 0.4, L/R = 7 ms) 3 A, 250 VAC 3 A, 30 VDC 5 A (see note) 250 VAC 125 VDC 5A 1,250 VA 300 W 1,250 VA 150 W 1 VDC, 1 mA 500 VA 150 W 1,250 VA 150 W 1 VDC, 100 A 500 VA 150 W 0.8 A, 250 VAC 1.5 A, 30 VDC 4-pole (bifurcated) Resistive load (cos = 1) 3 A, 250 VAC 3 A, 30 VDC Inductive load (cos = 0.4, L/R = 7 ms) 0.8 A, 250 VAC 1.5 A, 30 VDC
Max. switching 250 VAC voltage 125 VDC Max. switching 10 A current Max. switching 2,500 VA capacity 300 W Min. permissible load* 5 VDC, 1 mA
* Reference value. Note: Do not exceed the carry current of a Socket in use.
260
General-purpose Relay
MY
Characteristics
Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric withstand voltage Vibration resistance Shock resistance Life expectancy Ambient temperature Ambient humidity Weight Operating Operating Electrical 100 m max. 20 ms max. 20 ms max. Mechanical 18,000 operations/hr 1,800 operations/hr (under rated load) 1,000 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity) Destruction:10 to 55 Hz, 1.0 mm double amplitude Malfunction:10 to 55 Hz, 1.0 mm double amplitude Destruction:1,000 m/s2 (approx. 100G) Malfunction:200 m/s2 (approx. 20G) See the following table. -55C to 70C (-67F to 158F) with no icing (see note) 5% to 85% RH Approx. 35 g
Note: The values given above are initial values.
Life Expectancy Characteristics
Pole 2-pole 4-pole 4-pole (bifurcated) Mechanical life (at 18,000 operations/hr) AC:50,000,000 operations min. DC:100,000,000 operations min. 20,000,000 operations min. Electrical life (at 1,800 operations/hr under rated load) 500,000 operations min. 200,000 operations min. 100,000 operations min.
Approved Standards
VDE, UL, CSA, IMQ, CE
Precautions
Connections
Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays.
Mounting
Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement.
General-purpose Relay
MY
261
Engineering Data
Maximum Switching Power
MY2
Switching current (A)
MY4, MY4Z
Switching current (A)
AC resistive load AC inductive load (cos=0.4)
AC resistive load AC inductive load (cos=0.4)
DC resistive load
DC resistive load
DC inductive load (L/R=7 ms)
DC inductive load (L/R=7 ms)
Switching voltage (V)
Switching voltage (V)
Endurance
MY2 (Resistive Loads)
Endurance (x10 3 operations)
10000 5000 3000 1000 500 300 30 VDC 30 VDC 250 VAC
MY2 (Inductive Loads)
Endurance (x10 3operations)
10000 5000 3000 1000 500 300 250 VAC 30 VDC
30 VDC 250 VAC
100 50 30 10
250 VAC
100 50 30 10
Switching current (A)
Switching current (A)
MY4 (Resistive Loads)
Endurance (x10 3 operations)
10000 5000 3000 1000 500 300
30 VDC 30 VDC 250 VAC
MY4 (Inductive Loads)
Endurance (x10 3 operations)
10000 5000 3000
30 VDC
1000 500 300
250 VAC 30 VDC
100
250 VAC
100 50 30 10
250 VAC
50 30 10
Switching current (A)
Switching current (A)
262
General-purpose Relay
MY
MY4Z (Resistive Loads)
Endurance (x10 3 operations)
10000 5000 3000 1000 500 300 30 VDC 100 50 30 10 30 VDC 250 VAC
MY4Z (Inductive Loads)
Endurance (x10 3operations)
10000 5000 3000 1000 500 300 30 VDC 30 VDC 100 50 30 10 250 VAC
250 VAC
250 VAC
Switching Current (A)
Switching Current (A)
General-purpose Relay
MY
263
Dimensions
Note: All units are in millimeters unless otherwise indicated.
2-Pole Models
MY2N
2.6
Eight, 1.2 dia. x 2.2 long holes
0.5
28 max.
36 max.
6.4
21.5 max.
4-Pole Models
MY4N
2.6
Eight, 1.2 dia. x 2.2 long holes
0.5
28 max.
36 max.
6.4 21.5 max.
Models with Test Button
MY2IN
2.6
6.3
8
Eight, 1.2 dia. x 2.2 long holes
28 max. 5 80.5
14.2
36 max. 21.5 max.
MY4IN
2.6
6.3
8
Fourteen, 1.2 dia. x 2.2 long holes
0.5
28 max.
14.2
80.5
5
36 max. <1.417>
6.4
21.5 max.
264
General-purpose Relay
MY
Terminal Arrangement/Internal Connections (Bottom View)
MY2 MY2N/MY2IN (AC Models) MY2N/MY2IN (DC Models) MY2N-D2/MY2IN-D2 (DC Models Only)
MY2N-CR/MY2IN-CR (AC Models Only)
MY2N1/MY2IN1 (DC Models Only)
MY2N1-D2/MY2IN1-D2 (DC Models Only)
MY4(Z)
MY4(Z)N/MY4(Z)IN (AC Models)
MY4(Z)N/MY4(Z)IN (DC Models)
MY4(Z)N-D/MY4(Z)IN-D2 (DC Models Only)
MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only)
MY4(Z)N1/MY4(Z)IN1 (DC Models Only)
MY4(Z)N1-D2/MY4(Z)N1-D2 (DC Models Only)
General-purpose Relay
MY
265
Accessories (order separately)
Track-mounted Screwless Clamp Terminal Sockets
Item Socket Clip & release lever Nameplate Socket bridge Model 4-pole PYF14S PYCM-14S R99-11 Nameplate for MY PYDM-14SR PYDM-14SB PYDM-08SR PYDM-08SB 2-pole PYF08S PYCM-08S
Note: For complete specifications, see the datasheet at Omron's Knowledge Center on our website: www.knowledge.omron.com.
Sockets
Poles Front-connecting Back-connecting socket socket Solder terminals (DIN-track/screw mounting) Without clip With clip PYF08A-E PYF08A-N 4 PYF14A-E PYF14A-N PY14 PY14-Y1 PY14-02 PY08 PY08-Y1 PCB terminals PY08-02
2
Socket Specifications
Item Screwless clamp terminal socket Track-mounted socket Pole 2 4 2 4 Back-connecting socket 2 4 Model PYF08S PYF14S PYF08A-E PYF08A-N (see note 3) PYF14A-E PYF14A-N (see note 3) PY08(-Y1) PY08-02 PY14(-Y1) PY14-02 Note: 1. 2. 3. 4. 5. The values given above are initial values. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40C, reduce the current to 60%. The MY2(S) can be used at 70C with a carry current of 7 A. 3A Carry current 10 A 5A 7A 7 A (see note 4) 5A 5 A (see note 4) 7A 1,500 VAC, 1 min 100 M min. 2,000 VAC, 1 min 1,000 M min. Dielectric withstand voltage 2,000 VAC, 1 min Insulation resistance (see note 2) Less than 1,000 M
Socket Hold-down Clip Pairing
Relay type Poles Front-connecting socket (DIN-track/screw mounting) Socket Without 2-pole test button Without 2-pole test button 2-pole test button 2 4 2 PYF08A-E PYF08A-N PYF14A-E PYF14A-N PYF08A-E PYF08A-N PYC-E1 PY08 PYC-A1 PY14 Clip PYC-A1 Back-connecting socket Solder terminals Socket PY08 Clip PYC-P PYC-P2 PYC-P PYC-P2 PYC-P2 PCB terminals Socket PY08-02 PY14-02 PY08-02 Clip PYC-P PYC-P2 PYC-P PYC-P2 PYC-P2
266
General-purpose Relay
MY
Mounting Plates for Sockets
Socket model PY08, PY14 For 1 socket PYP-1 For 18 sockets PYP-18 For 36 sockets PYP-36
Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.
DIN Rail Track and Accessories
Description Mounting rail (length = 500 mm) Mounting rail (length = 1,000 mm) End Plate Spacer Model PFP-50N PFP-100N, PFP-100N2 PFP-M PFP-S
General-purpose Relay
MY
267
Dimensions
Unit: mm (inch) Socket Dimensions Terminal arrangement/ internal connections (top view)
Eight, M3 x 8 sems screws
Mounting holes
PYF08A-E
Two, 4.2 x 5 mounting holes
Two, M3, M4, or 4.5-dia. holes
72 max.
(TOP VIEW)
23 max. 31 max.
Note: Track mounting is also possible. Refer to page 12 for supporting tracks.
Two, M3, M4, or 4.5-dia. holes
PYF14A-E
Two, 4.2 x 5 mounting holes
Fourteen, M3 x 8 sems screws
72 max.
29.5 max. 31 max.
(TOP VIEW) Note: Track mounting is also possible. Refer to page 12 for supporting tracks.
PY08/PY08-Y1
(See note)
Eight, 3 x 1.2 elliptical holes
25.5 max. 29.5 max.
20 max. 42 max.
24 max.
Note: The PY08-Y1 includes sections indicated by dotted lines. PY08-02
25.5 max. 29.5 max.
22 max. 16.5 max.
Eight, 1.3-dia. holes
268
General-purpose Relay
MY
Socket
Dimensions
Terminal arrangement/ internal connections (top view)
Mounting holes
PYF08A-N
4 42 8 44
22 max.
42 4 44 8 12 1 14 5
1 12 5 14
3.0 dia. 18.7 3.5 dia. or M3
67 max.
PYF-08A-N
41 12 11 9
73
A1
12 41
9 11
A2
A2
14 14 13 A2 A2 A1
14
14
13
Note: Track mounting is also possible. Refer to page 12 for supporting tracks.
30 max.
PYF14A-N
4 42 8 44 3 32 7 34 2 22 6 24 1 12 5 14
42 4 44 8
32 3 34 7
22 2 24 6
12 1 14 5
Two, 4.5 dia. or M4
67 max.
PYF-14A-N
41 12 31 11 21 10 11 9
26 73 12 11 10 9 41 31 21 11 30 max. 14 14 A2 A2 13 A1
A2 14
A2 14
A1 13
Note: Track mounting is also possible. Refer to page 12 for supporting tracks.
29.5 max.
PY14/PY14-Y1
(See note)
Fourteen, 3 x 1.2 elliptical holes
25.5 max. 29.5 max.
42 max.
20 max.
24 max.
Note: The PY14-Y1 includes sections indicated by dotted lines.
PY14-02
25.5 max. 29.5 max.
22 max. 16.5 max.
Fourteen, 1.3-dia. holes
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.
General-purpose Relay
MY
269
Socket
Dimensions
Terminal arrangement/ internal connections (top view)
36.5 max.
Mounting height (with lever)
PYF14S
72.6 typ.
31 max.
28.6
85 max.
Note: Track mounting only. Note: Pole-2 and pole-3 cannot be used with the MY2 type. Use pole-1 (terminal numbers 11, 14, 12) and pole-4 (terminal numbers 41, 44, 42).
38.2 max. 36.5 max.
PYF08S
23.2 max.
73.6 typ.
28.6
Note: Track mounting only.
85 max.
(5.3)
Socket Bridge
Insulating coating
L 1.4 dia. conductor (See note 1.)
Model number PYDM-14SR PYDM-14SB PYDM-08SR PYDM-08SB
Length L (mm) 27.50.3 19.70.3
Color of insulating coating Red Blue Red Blue
Item Rated ON current Rated insulation voltage Temperature rise Dielectric strength Ambient operating temperature
Characteristic 10 A 250 VAC 35C max. 1,500 VAC for 1 minute -55 to 70C
Note: 1. The relationship between the model number, the length L, and the color of the insulating coating is shown above. 2. The insulating coating must be able to withstand a voltage of 1,500 V for 1 minute. Use either PE or PA as the material of the insulating coating.
3. The positions of the ends of the insulating coating must not vary more than 0.5 mm. 4. The characteristics of the socket bridge are shown above.
270
General-purpose Relay
MY
Clip and Release Levers
PYCM-14S PYF14S Lever PYCM-08S PYF08S Lever
16 typ. 28 typ. 6 typ. 26.5 typ. 21.5 typ.
54.4 typ. 4.1 typ. 52.5 typ. 5.4 typ. 32.7 typ. 29.6 typ. 3 typ. 6.41 typ.
Hold-down Clips
PYC-A1 PYC-A1 (2 pcs per set) (2 pcs per set) PYC-E1 PYC-E1 (2 pcs perper set) (2 pcs set)
36.3
36.3
4.5 4.5 1.2 4.50.1
5.75
4.25
PYC-P PYC-P
5
PYC-P2 PYC-P2
10
29 max. 3.3
28
38.5
General-purpose Relay
MY
271
Mounting Plates for Back-connecting Sockets
PYP-1 PYP-1 PYP-36 PYP-36
Two, 3.4-dia. holes 72 elliptical holes
t=1.6
PYP-18 PYP-18
72 elliptical holes
Mounting Track and Accessories
DIN Rail Track
PFP-50N/PFP-100N
7.30.15 4.5 350.3 1 15 25 10 25 1000 (500) * 25 10 25 15 (5) 270.15
Note: The figure in the parentheses is for PFP-50N.
PFP-100N2
16 4.5 350.3 27 15 25 25 1000 25 10 25 15 24 1 29.2 1.5
10
End Plate
PFP-M
10 M4 x 8 pan head screw 6.2 1.8
1 50 11.5 10 M4 spring washer 1.3 4.8 1.8 35.5 35.3
272
General-purpose Relay
MY
Spacer
PFP-S
5
16 12
44.3
34.8
16.5
Approved Standards
VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435)
No. of poles 2 4 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC Contact ratings 10 A, 250 VAC (cos=1) 10 A, 30 VDC (L/R=0 ms) 5 A, 250 VAC (cos=1) 5 A, 30 VDC (L/R=0 ms) Operations 10 x 103 100 x 103 MY4Z AC; 50 x 103
UL Recognized (File No. 41515)
No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 30 VDC (general purpose), 40C 10 A, 250 VAC (general purpose), 40C 5 A, 30 VDC (general purpose), 40C (Same polarity) 5 A, 250 VAC (general purpose), 40C (Same polarity) Operations 6 x 103
CSA Certified (File No. LR31928)
No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 30 VDC 10 A, 250 VAC 5 A, 250 VAC (same polarity) 5 A, 30 VDC (same polarity) Operations 6 x 103
IMQ (File No. EN013 to 016)
No. of poles 2 4 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC Contact ratings 10 A, 30 VDC 10 A, 250 VAC 5 A, 250 VAC 5 A, 30 VDC Operations 10 x 103 100 x 103 MY4Z AC; 50 x 103
LR Recognitions (File No. 98/10014)
No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 250 VAC (resistive) 2 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 2 A, 30 VDC (L/R=7 ms) 5 A, 250 VAC (resistive) 0.8 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 1.5 A, 30 VDC (L/R=7 ms) Operations 50 x 103
4
50 x 103
General-purpose Relay
MY
273
SEV Listings (File No. 99.5 50902.01)
No. of poles 2 4 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 250 VAC 10 A, 30 VDC 5 A, 250 VAC 5 A, 30 VDC Operations 10 x 103 100 x 103 MY4Z AC; 50 x 103
Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change.
PYF-S Installation Notes
Tools
A flat-blade screwdriver should be used to mount the cables.
Applicable Screwdriver
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Flat-blade, Parallel-tip
2.5 dia. (3.0 mm max.)
Flat-blade, Flared-tip
Cannot be used.
Examples: FACOM AEF.2.5 x 75E VESSEL No. 9900-(-)2.5 x 75 WAGO 210-119 WIHA 260/2.5 x 40 (AEF. 3 x 75E) (No. 9900-(-)3 x 100) (260/3 x 50)
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
Applicable Wires
Applicable Wire Sizes
0.2 to 1.5 mm2, AWG24 to AWG16
Applicable Wire Type
Solid wires, stranded wires, flexible wires, or wires with ferules can be used. (See note 1.) < 2.2 Diameter D (mm) 3.2 (3.5: see note 2.) Conductor diameter d (mm) or length of sides a and b (mm) 1.9 Note: 1. If the overall diameter of the wire is less than 2.2 mm, do not insert the wire past the conductor. Refer to the following diagrams.
Wires with Ferules
2. If the overall diameter of the wire is over 3.2 mm, it will be difficult to use double wiring.
274
General-purpose Relay
MY
Examples of Applicable Wires (Confirmed Using Catalog Information)
Type of wire Equipment wire 2491X BS6004 Switchgear BS6231 Switchgear BS6231 Tri-rated control and switchgear Conduit UL1007 UL1015 UL1061 UL1430 Conductor type Flexible Solid Solid Flexible Flexible Stranded Flexible Flexible Flexible Flexible 18AWG 18AWG 16AWG 18AWG 0.5 mm2 1.0 mm2 0.5, 0.75 mm 1.5 mm2 16AWG 18AWG, 16AWG
2 2
See note 1, above.
Recommended wire sizes See note 2, above. 0.5, 0.75, 1.0 mm2 1.5 mm2 1.5 mm2 1.0 mm2
0.5, 0.75, 1.0, 1.5 mm
Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 8 to 9 mm.
8 to 9 mm
Fig. 1 Exposed Conductor Length
Use the following wiring procedure. 1. Insert the specified screwdriver into the release hole located beside the wire connection hole where the wire is to be inserted.
2. Insert the exposed conductor into the wire connection hole.
Insert
Wire connection holes Release holes
3. Pull out the screwdriver.
Fig. 2 Wire Connection Holes and Release Holes
Wire connection hole Pull out
Release hole Insert Screwdriver
Note: Use no more than 2 wires per terminal, 1 wire per hole.
Fig. 3 Section A-A of Fig. 2
General-purpose Relay
MY
275
Precautions
Precautions for Connection
* Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the coil spring or cracks in the housing) or cause deterioration of insulation. * Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit.
General Precautions
* Use the clip to prevent relays floating or falling out of the socket. * Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. * Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. * Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. * Do not pour water or cleansing agents on the product. Doing so may result in electric shock. * Do not use the socket in locations subject to solvents or alkaline chemicals. * Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. * Do not dispose of the product in fire.
* Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. (There are two wiring holes for each terminal.)
Removing from Mounting Rail
To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below.
Screwdriver
* Insert the screwdriver along the hole wall as shown below.
Fixture rail Screwdriver
* If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. * Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly.
276
General-purpose Relay
MY
Omron Electronic Components, LLC
Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER'S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER'S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference.
(b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller's practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller's website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision.
General-purpose Relay
MY
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information.
Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC COMPONENTS LLC
55 E. Commerce Drive, Suite B Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com
847-882-2288
Cat. No. X301-E-1 06/09 Specifications subject to change without notice Printed in USA
General-purpose Relay
MY


▲Up To Search▲   

 
Price & Availability of MY2IN-CR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X